Difference between revisions of "EAPIR-8 Restore Factory Defaults"
Jump to navigation
Jump to search
(Created page with "A EAPIR access panel may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can e...") |
|||
Line 2: | Line 2: | ||
=Reset to Factory Default Settings with Activated DHCP= | =Reset to Factory Default Settings with Activated DHCP= | ||
− | [[File: | + | [[File:EAPIR factory default1.PNG|thumb|130px|Factory Default with IP address from DHCP server]] |
To reset: | To reset: | ||
:1. While '''pressing any button''', power up the station by connecting to a PoE switch. | :1. While '''pressing any button''', power up the station by connecting to a PoE switch. | ||
Line 18: | Line 18: | ||
=Reset to Factory Default Settings with Static IP= | =Reset to Factory Default Settings with Static IP= | ||
− | [[File: | + | [[File:EAPIR factory default2.PNG|thumb|130px|Factory Default with Static IP Address]] |
To reset: | To reset: | ||
:1. While '''pressing any button''', power up the station by connecting to a PoE switch. | :1. While '''pressing any button''', power up the station by connecting to a PoE switch. |
Revision as of 10:07, 8 February 2018
A EAPIR access panel may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
Reset to Factory Default Settings with Activated DHCP
To reset:
- 1. While pressing any button, power up the station by connecting to a PoE switch.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 5 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button to make the station say its IP address.
Factory default values
- Station IP address: (determined by DHCP server)
- Username: admin
- Password: alphaadmin
Reset to Factory Default Settings with Static IP
To reset:
- 1. While pressing any button, power up the station by connecting to a PoE switch.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 3 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button to make the station say its IP address.
Factory default values
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin