Difference between revisions of "Backup Amplifier Wiring"

From exigoWiki
Jump to navigation Jump to search
Line 45: Line 45:
  
 
Please be aware that the standard backup wiring must also be done to make the optional switch-over work.
 
Please be aware that the standard backup wiring must also be done to make the optional switch-over work.
 +
 +
== Availability ==
 +
This function is available from Exigo 1.3 and newer.
  
 
[[Category:Exigo features]]
 
[[Category:Exigo features]]

Revision as of 13:48, 12 December 2016

This article describes how to wire the backup amplifier solution. Exigo ENA Amplifiers have inbuilt support for backup amplifier switch-over where one amplifier can be designated as backup for up to six other amplifiers.

Wiring

The backup amplifier needs to be wired to the amplifier(s) it should monitor:

  • One control output (24V DC) from the backup amplifier is connected to each of the backed-up amplifiers (star wiring).
  • The speaker loop outputs from the backup amplifier are connected to the backup inputs on all amplifiers being backed up (bus wiring).

In addition, an optional function on a control input on the backup amplifier can trigger the backup functionality. This will ensure an even faster switch-over if the defective amplifier has a power issue.

  • Wire the Control Output on the backed-up amplifier to the Control Input on the backup amplifier.


Standard Backup Wiring Example

In the figures below, we have a backup amplifier that is on hot standby for two amplifiers.

Control Output/Input Wiring:

Control output to control input wiring


The red and blue wiring is the control outputs from the backup amplifier to the two backed-up amplifiers:

  • Control Output 1 (24V DC) on the Backup Amplifier is wired to the control in (labeled CTRL IN) on Amplifier 1.
  • Control Output 2 (24V DC) on the Backup Amplifier is wired to the control in (labeled CTRL IN) on Amplifier 2.

Speaker Output/Input Wiring:


The orange and green wires are the 100V speaker lines:

  • Channel 1 output on the Backup Amplifier is wired to channel 1 backup input (labeled BACK-UP 1) on Amplifier 1 and Amplifier 2.
  • Channel 2 output on the Backup Amplifier is wired to Channel 2 backup input (labeled BACK-UP 2) on Amplifier 1 and Amplifier 2.

Optional Switch-Over Wiring Example

The figure below illustrates how the optional switch-over wiring is done.

Optional switch-over wiring


The red and blue wiring are the control outputs from the backed-up amplifiers to the backup amplifiers:

  • Control Output 1 (NO - Normally Open) on Amplifier 1 is wired to Control Input 1 on the Backup Amplifier.
  • Control Output 2 (NO - Normally Open) on Amplifier 2 is wired to Control Input 2 on the Backup Amplifier.

Please be aware that the standard backup wiring must also be done to make the optional switch-over work.

Availability

This function is available from Exigo 1.3 and newer.