Difference between revisions of "LED Brightness"

From exigoWiki
Jump to navigation Jump to search
(Access Panels)
(Access Panels)
Line 19: Line 19:
 
On indoor access panels ([[ECPIR-P]] and [[ECPIR-3P]]) it is possible to set the LED brightness both locally and in [[:Category:EMT | EMT]].<br>
 
On indoor access panels ([[ECPIR-P]] and [[ECPIR-3P]]) it is possible to set the LED brightness both locally and in [[:Category:EMT | EMT]].<br>
 
It is also possible to do a test of the LED's on the panel. <br>
 
It is also possible to do a test of the LED's on the panel. <br>
This is done by using the input action ['''Panel Lamp Test'''] to a DAK (or control input) on the panel.
+
This is done by using the input action [[Panel Lamp Test]] to a DAK (or control input) on the panel.
 
=== Local Adjustment ===
 
=== Local Adjustment ===
 
The intensity of the LED and the backlight in the keys can be adjusted by pressing the dimmer button:  
 
The intensity of the LED and the backlight in the keys can be adjusted by pressing the dimmer button:  

Revision as of 15:30, 5 December 2016

This article explains how to adjust the LED brightness on both central equipment (ESC1 & ENA) and indoor access panels.

Central Equipment

LED brightness can be adjusted both locally an in EMT.

Local Adjustment

On both the ESC1 and ENA the local LED setting can be found under Settings -> Display:

LED brightness


From this menu it is possible to adjust the LED and display brightness up and down.
It is also possible to test the LED's.

EMT Settings

It is also possible to set the LED brightness in EMT.
In the device tree go to the ESC1 or ENA -> LED:

LED brightness in EMT


For information regarding EMT vs local settings see this article.

Access Panels

On indoor access panels (ECPIR-P and ECPIR-3P) it is possible to set the LED brightness both locally and in EMT.
It is also possible to do a test of the LED's on the panel.
This is done by using the input action Panel Lamp Test to a DAK (or control input) on the panel.

Local Adjustment

The intensity of the LED and the backlight in the keys can be adjusted by pressing the dimmer button:

LED brightness adjustment on indoor access panels


The light intensity is increased or decreased by pressing the plus (+) or minus (-) side of the dimmer button respectively.

EMT Settings

It is also possible to set the LED brightness in EMT.
In the device tree go to the ECPIR-P or ECPIR-3P -> LED:

LED brightness in EMT


For information regarding EMT vs local settings see this article.