Difference between revisions of "Setting up a small system"

From exigoWiki
Jump to navigation Jump to search
(Step 2: Primary System Controller Setup)
Line 38: Line 38:
  
  
[[File:Amc IP Interface 1.png|left]]
+
[[File:Amc IP Interface 1.png|thumb|left|500px|Connecting ]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
* Enter the appropriate IP address (10.1.10.21) in the '''npe_eth1''' field
 
* Enter the appropriate IP address (10.1.10.21) in the '''npe_eth1''' field

Revision as of 09:26, 29 June 2016

This page will explain how to configure and test a small Exigo system.

Step 1: IP addresse

Each device will need to be configured with an IP address and subnet which is in range of the AMC-IP card.

Table below lists IP range for a small system with one amplifier and on access panel. All subnets are set to 255.255.255.0

Device IP Directory number
PSC 10.1.0.21
ESC-1 10.1.0.20 013010
ENA 10.1.0.30 012010
ECPIR-3P 10.1.0.50 011010


Step 2: Primary System Controller Setup

Open up the front of the ESC1 System Controller. Connect your computer to eth0.

  1. Open a web browser and enter the default IP address of port npe_eth0: 169.254.1.5
  2. Log in with username: admin and password: alphaadmin
  3. Select System Configuration > Interfaces


Connecting


  • Enter the appropriate IP address (10.1.10.21) in the npe_eth1 field

Step 3: Secondary System Controller Setup

Connect your computer to eth1 (on the back of the ESC1 System Controller).

To find th IP adress of the Secondary System Controller:

  • Turn the menu selection knob on the system controller to select Settings > Network to see the IP address on the display.

To configure the IP address and directory number:

  1. Open a web browser and enter IP address: 169.254.x.x
  2. Log in with username: admin and password: alphaadmin
  3. Select Station Main > Main Settings


Secondary Controller Settings 1.png


Set the following values:

  • Station Mode: Use Exigo
  • Registration Settings:
  • Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
    • Directory Number: 013010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
  • IP Settings: Static IP
    • IP-address: 10.1.0.20
    • Subnet-mask: 255.255.255.0
    • Gateway: 10.1.0.1

Step 4: ENA Amplifier Setup

Connect your computer to eth1 (on the back of the ENA Amplifier).

To find th IP adress of the ENA Amplifier:

  • Turn the menu selection knob on the Amplifier to select Settings > Network to see the IP address on the display.

To configure the IP address and directory number:

  1. Open a web browser and enter IP address: 169.254.x.x
  2. Log in with username: admin and password: alphaadmin
  3. Select Station Main > Main Settings


ENA Settings 1.png



Set the following values:

  • Station Mode: Use Exigo
  • Registration Settings:
  • Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
    • Directory Number: 012010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
  • IP Settings: Static IP
    • IP-address: 10.1.0.30
    • Subnet-mask: 255.255.255.0
    • Gateway: 10.1.0.1

Step 5: ECPIR-3P Setup

Configuration is done via the access panel’s web interface. After making sure that the access panel is connected to the same LAN and logical subnet as your PC, follow the procedure described below.

To configure the IP address and directory number:

  1. Open a web browser and enter IP address: 169.254.x.x
  2. Log in with username: admin and password: alphaadmin
  3. Select Station Main > Main Settings


ECPIR Settings 1.JPG



Set the following values:

  • Station Mode: Use Exigo
  • Registration Settings:
  • Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
    • Directory Number: 011010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
  • IP Settings: Static IP
    • IP-address: 10.1.0.50
    • Subnet-mask: 255.255.255.0
    • Gateway: 10.1.0.1

Step 6: Install Exigo Management Tool (EMT)

Install EMT on your computer. See this page for details: Category:EMT

Step 7: Exigo Management Tool Setup

  • Start the Exigo Management Tool
  • Click Projects at the lower-left of the window.
EMT Setup 1.png


  • Click New
EMT Setup 2.png


  • Click the New Database tab
  • Click the right-arrow icon at the bottom of the window
EMT Setup 3.png


  • Enter a project name in the Project field
  • Select the A-B System tab
  • Click the right-arrow icon at the bottom of the window
EMT Setup 4.png


  • Set 2 for the Number of Discrete Zones
  • Enter IP address 10.1.0.21 in Domain Address
  • Click the right-arrow icon at the bottom of the window
EMT Setup 5.png


Select the desired monitoring:

  • Select Eth1 for the Rack Devices
  • Select AC Monitoring
  • Select Eth1 for the Access Panels and Kits
EMT Setup 6.png


Select the desired Advanced Settings:

  • Default setting is OK. This can be changed later if needed.
  • Click the right-arrow icon at the bottom of the window to display a project summary
EMT Setup 7.png


  • Click Finish to complete the setup of the project

After setup, your Exigo system should look something like the following:

EMT Setup 8.png


Step 8: Exigo Management Tool System Configuration

When the Project is created in EMT it is time to do configuration on the System.

Assigning the ECPIR-3P Access Panel to the System:

  • Click Components at the lower-left of the window.
  • Click Devices from the menu box
  • Under Console Mounted Access Panels drag-and-drop ECPIR-3P to System
EMT Config 1.png


The access panel will now appear as ECPIR-3P 1 in the device list under System.

Assigning Channels on Amplifier to Zones:

  • Select ENA2200 A1 > Audio Lines > Line > Amplifier output channel 1
  • Drag-and-drop Amplifier output channel 1 to Zone 1 under PA Zones
EMT Config 2.png


  • Repeat the procedure to assign channel 2 on the amplifiers to Zone 2.

Assigning Zone to the PPT Button

  • Select System > ECPIR-3P 1 > Programmable Keys > ptt > press_actions
EMT Config 3.JPG


  • In the detailed view select All under Destination

Do the same for release_action:

  • Select System > ECPIR-3P 1 > Programmable Keys > ptt > press_release
  • In the detailed view select All under Destination

Step 9: Upload database

In the Navigation pane, select Projects view.

EMT Upload 1.png


  • Press Send to upload the new configuration to the Exigo system