Difference between revisions of "Flowire Compatibility Overview"

From exigoWiki
Jump to navigation Jump to search
Line 34: Line 34:
 
|}
 
|}
  
  {{Note}} ''Updating EX-stations to version 4.1.2.13 '''must''' be done by using a FCDC2.''
+
  {{Note}} ''Updating EX-stations to version 4.1.2.13 '''must''' be done by using a FCDC1/2.''
 +
 
 +
== Spare Part Scenarios ==
 +
=== Redundant Exigo A-B configuration ===
 +
# Replacing a FCDC1/2 or EX-stations with old software with FCDC1/2 or same type EX-station with old software: No additional actions needed.
 +
# Replacing one or more of the FCDC1/2 with old software with FCDC3 in a system with FCDC1/2 or EX-stations still in cluster: Update remaining FCDC1/2 and EX-stations with new software. Update of EX-stations '''must''' be done using a FCDC1/2.

Revision as of 14:07, 3 February 2020

This article explains the compatibility between the different Flowire units and the different software versions.

There are 3 different Flowire models:

The following table shows software versions needed in FCDC1/2 or EX-stations to achieve compatibility between FCDC3 and FCDC1, FCDC2 and EX-stations.
Old software for FCDC1/2 and EX-stations is 4.1.3.12 and older.
New software for FCDC1/2 and EX-stations is 4.1.3.13 and newer.


Stations FCDC3 FCDC1/2 &
EX-Station w/old SW
FCDC1/2 &
EX-Station w/new SW
FCDC3 Full compatibility No connection Full compatibility
FCDC1/2 &
EX-Station w/old SW
No connection Full compatibility Limited compatibility
(upgrade possible)
FCDC1/2 &
EX-Station w/new SW
Full compatibility Limited compatibility
(upgrade possible)
Full compatibility
Note.PNG Updating EX-stations to version 4.1.2.13 must be done by using a FCDC1/2.

Spare Part Scenarios

Redundant Exigo A-B configuration

  1. Replacing a FCDC1/2 or EX-stations with old software with FCDC1/2 or same type EX-station with old software: No additional actions needed.
  2. Replacing one or more of the FCDC1/2 with old software with FCDC3 in a system with FCDC1/2 or EX-stations still in cluster: Update remaining FCDC1/2 and EX-stations with new software. Update of EX-stations must be done using a FCDC1/2.