Difference between revisions of "SNMP recommended parameters"
Jump to navigation
Jump to search
(→Exigo 1.2.3.13) |
(→Exigo 1.2.3.13) |
||
Line 33: | Line 33: | ||
|- | |- | ||
| 1.3.6.1.4.1.26122.3.3.2.1.2 || fanString || During startup || SSC + ENA || | | | 1.3.6.1.4.1.26122.3.3.2.1.2 || fanString || During startup || SSC + ENA || | | ||
+ | |- | ||
+ | | 1.3.6.1.4.1.26122.3.3.2.1.3 || fanValue || Once every 60 second || SSC + ENA || | | ||
|- | |- | ||
|} | |} |
Revision as of 12:48, 12 June 2019
This article describes the SNMP parameters that are recommended to monitor.
Exigo 1.2.3.13
Exigo 1.2.3.13 is using SNMPv1.
OID | Logical name | Frequency | Unit | Priority |
---|---|---|---|---|
Memory usage MIB2 | Memory usage | Once every 60 second | All | |
1.3.6.1.4.1.26122.3.1.4 | infoAmplifierType | During startup | All | |
1.3.6.1.4.1.26122.3.1.1 | infoPackageVersion | During startup | All | |
1.3.6.1.4.1.26122.3.2 | temp | |||
1.3.6.1.4.1.26122.3.2.1 | tempTableCount | |||
1.3.6.1.4.1.26122.3.2.2.1.2 | tempSensorName | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.2.2.1.7 | tempAverageString | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.2.2.1.8 | tempAverageValue | Twice every 60 second | SSC + ENA | |
1.3.6.1.4.1.26122.3.3 | fan | |||
1.3.6.1.4.1.26122.3.3.1 | fanTableCount | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.3.2.1.2 | fanString | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.3.2.1.3 | fanValue | Once every 60 second | SSC + ENA |