Line 188: | Line 188: | ||
==== EMT - Zones could loose name if "done" was not pressed ==== | ==== EMT - Zones could loose name if "done" was not pressed ==== | ||
+ | |||
+ | ==== The list of possible faults on the Exigo wiki is now updated ==== | ||
+ | : [[Fault_Indication_System_Message Fault Indication System Message]] |
Revision as of 12:15, 26 November 2018
Contents
- 1 Exigo 1.4.3.0
- 1.1 Software included in EXIGO-1.4.3.0.zip
- 1.2 New Features
- 1.2.1 IP-LCM support in Alphacom / Pulse / SIP
- 1.2.2 Exigo systems can now be integrated with Pulse systems
- 1.2.3 EMT - Scan IP range for devices now available
- 1.2.4 SNMP traps are now supported by all Exigo devices
- 1.2.5 Exigo now supports distributed automatic volume controllers
- 1.2.6 ENA2100-AC is now supported in Exigo systems
- 1.2.7 New ZAP rpcs available for remote integration
- 1.2.8 Audio bypass is now supported on all Exigo devices
- 1.2.9 Zone select can now deselect when activities are started or stopped
- 1.2.10 Adjustable delay of missing devices
- 1.3 Bugfixes and improvements
- 1.3.1 Detailed channel state in SNMP MIB
- 1.3.2 Access panels part of zones can now correctly receive messages, alarms and live speech
- 1.3.3 EMT - Database will handle Exigo Net system ID settings better
- 1.3.4 EMT - An error window without effect would sometimes appear when changing the name of a zone
- 1.3.5 EMT - Actions can now be copied to paired devices successfully
- 1.3.6 Headphone output on ENA2200 and ENA2400 will now not be active unless activated from the GUI
- 1.3.7 Improved handling of audio streams on amplifiers
- 1.3.8 EMT - "Always include" field removed from local mute action
- 1.3.9 AMC-IP will now correctly remove Exigo settings immediatly after a factory default
- 1.3.10 EMT - Password for PSC can now be changed
- 1.3.11 EMT - Advanced program control sequence can now be correctly copy/pasted
- 1.3.12 TKIE-2 relay 2 can now be configured correctly without rebooting the device
- 1.3.13 Program volume control function can now use dynamically selected zones
- 1.3.14 EMT - PSC will now reboot correctly if changes to the SIP interface is done
- 1.3.15 EMT - Tooltip for zone selection is now correct
- 1.3.16 EMT - EMT can now correclty generate a database directly from a GET when controller B is missing
- 1.3.17 EMT - Zone names with illegal characters will now not be allowed
- 1.3.18 Incoming SIP Calls will now be correctly parsed
- 1.3.19 EMT - Name of zone will now always save when the done button is pressed
- 1.3.20 EMT - Improvements to zone handling when an access panel is added to the zone
- 1.3.21 Voice activity detection can now be used on EX panels to automatically trigger actions
- 1.3.22 EMT - Getting a database from a running system will now correctly get any volume adjustments done to the Exigo amplifiers
- 1.3.23 EMT - Databases made with EMT 1.4 will now correctly set "use global settings" for SNMP on all devices
- 1.3.24 Control outputs can now be correctly reconfigured from fault indication to audio activity without rebooting the device
- 1.3.25 Volume control normalized for IP speakers and Exigo amplifiers
- 1.3.26 Various typos fixed in fault message for ESC1 GUI
- 1.3.27 EMT - Volume settings are now availabile on all devices
- 1.3.28 EMT - Exigo 1.2 Databases can now be opened in EMT 1.4 and newer
- 1.3.29 EMT - Parallel wired devices will now be correctly configured
- 1.3.30 ESC1 - All latin letters including æøå supported in GUI
- 1.3.31 Exigo database is now completely deleted from AMC-IP board during a factory default
- 1.3.32 ESC1 - Internal network recovery mechanisms added
- 1.3.33 EMT - Volume Override Priority was not corectly fetched from the PSC with a GET operation
- 1.3.34 Programs will now merge correctly regardless of how Zone Selection is set up
- 1.3.35 Live speech will now always start correctly after a "rejected" call
- 1.3.36 Recall is now correctly timing out if timeout is used
- 1.3.37 EMT - Clear all activity will now not have destination field if "all" is selected
- 1.3.38 EMT - Adding an amplifier to more than one zone will now always generate a "multiple zones" warning
- 1.3.39 Live speech with "wait for PTT" and no dynamic zones selected will now not light the green led
- 1.3.40 Non-existing power sources reported as faulty
- 1.3.41 ECPIR volume settings can now be adjusted even if the access panel is not connected to a server
- 1.3.42 Call escalation with no zones selected will now correctly be ignored instead of crashing the access panel
- 1.3.43 Exigo devices will now listen to the same NTP server if more than one is configured
- 1.3.44 (Bug 1.3.3.1) Dummy zones which does not contain devices can now be correctly called again
- 1.3.45 EMT - Keys on main panel will sort first for devices which use EMBDR-8
- 1.3.46 EMT - Zones could loose name if "done" was not pressed
- 1.3.47 The list of possible faults on the Exigo wiki is now updated
Exigo 1.4.3.0
Release status: Coming soon Release date: TBD Software collection file: EXIGO-1.4.3.0.zip
Software included in EXIGO-1.4.3.0.zip
Product | Version | Product description |
VSF-Turbine | VSFT-4.10.3.0 | Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM. |
AlphaSys Firmware | 13.0.3.0 | Firmware for the ESC1 (Primary System Controller/AMC-IP board) |
VS-EMT Exigo Management Tools | EMT-1.4.3.0 | Configuration tool, installed on a Windows PC |
VSF-Inca | TBD | Special Exigo software for the CRM-V based panel |
VS-DEVICE-MIB | TBD | SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools |
New Features
IP-LCM support in Alphacom / Pulse / SIP
- IP-LCM is now supported in Exigo systems. This device have:
- 8 robust high power relays
- 8 robust inputs
- Powered via the TKIS-2 kit with PoE, PoE inject or external power supply
- All connections and features from the TKIS-2 kit available
Exigo systems can now be integrated with Pulse systems
- Using the SIP interface on Exigo systems allows for integration both ways to pulse systems
EMT - Scan IP range for devices now available
- New tool in Operation view to scan an IP range for Exigo devices. From the list of discovered devices it is possible to send a command to the device to make the fault led blink (works for ENA, Access Panel and SSC devices).
- By default, the fault led will blink 4 times, 2 blinks pr second. The number of blinks and blink rate can be changed in Options -> Configuration Options.
- From the list of discovered devices it is also possible to open the device's Web Configuration page in the default browser.
SNMP traps are now supported by all Exigo devices
- SNMP traps for faults are now supported by all Exigo devices. Configuration is done via EMT.
Exigo now supports distributed automatic volume controllers
- Distributed Automatic Volume Controllers (dAVC) is TKIS-2 kits which measures background noise in an area and can adjust the volume settings for an amplifier or IP speaker so that the audio is audible above the noise.
- DAVC devices is monitored as other devices in the Exigo system.
- Zones with dAVC devices can have "volume override" functionality. Activities with priorities above this threshold will use full volume efficiently ignore background noise adjustments.
- DAVC Control of zone can be based on: highest, average or average mid. Both average require at least four dAVC devices.
- Disable AVC function can be used to selectively disable dAVC functionality per zone.
- Adjustment mode can be positive or negative between two thresholds.
- Advanced options where attack rate, decay rate, hysteresis and lock out time are available
ENA2100-AC is now supported in Exigo systems
- Advanced line monitoring and Lets supported
- Hardware audio bypass supported
- 2 control outputs with 200mA@24Vdc each
- 2 control inputs
- Supported in Exigo mode and Alphacom systems
New ZAP rpcs available for remote integration
- Restart of Class-D module
- Identification of devices by toggling fault led
- Remote toggling of control outputs
Audio bypass is now supported on all Exigo devices
- Bypass will route audio directly from the line input to both audio output channels based on the following configuration choices:
- Always on: This allows the amplifier to operate standalone mode without ESC1 or Alphacom
- Idle: This allows the amplifier to have bypass activated when no digital audio is present.
- No connection: This allows the amplifier to activate bypass if it loose connection to ESC1 or Alphacom
- Always off: This is default for Exigo amplifiers and audio bypass will never be activated
- ENA2100-AC: Hardware bypass available for instant forwarding
- ENA2200, ENA2400-DC, ENA2400-AC: Audio bypass available after software is up
Zone select can now deselect when activities are started or stopped
- This gives more options to how zone select should behave in relation to activities started from the access panels
Adjustable delay of missing devices
- It is now possible on a per device level to adjust a delay before the device is reported missing. Default is 0 seconds of delay before the device is reported missing.
Bugfixes and improvements
Detailed channel state in SNMP MIB
- Detailed information about the actual state of the audio channel is now included in the SNMP MIB.
Access panels part of zones can now correctly receive messages, alarms and live speech
EMT - Database will handle Exigo Net system ID settings better
EMT - An error window without effect would sometimes appear when changing the name of a zone
EMT - Actions can now be copied to paired devices successfully
Headphone output on ENA2200 and ENA2400 will now not be active unless activated from the GUI
Improved handling of audio streams on amplifiers
EMT - "Always include" field removed from local mute action
AMC-IP will now correctly remove Exigo settings immediatly after a factory default
EMT - Password for PSC can now be changed
EMT - Advanced program control sequence can now be correctly copy/pasted
TKIE-2 relay 2 can now be configured correctly without rebooting the device
Program volume control function can now use dynamically selected zones
EMT - PSC will now reboot correctly if changes to the SIP interface is done
- A manual reboot was necessary for any changes to be enabled and this will happen automatically now.
EMT - Tooltip for zone selection is now correct
EMT - EMT can now correclty generate a database directly from a GET when controller B is missing
EMT - Zone names with illegal characters will now not be allowed
Incoming SIP Calls will now be correctly parsed
- Sometimes the source nummer of an incoming SIP call would add a digit
EMT - Name of zone will now always save when the done button is pressed
EMT - Improvements to zone handling when an access panel is added to the zone
Voice activity detection can now be used on EX panels to automatically trigger actions
EMT - Getting a database from a running system will now correctly get any volume adjustments done to the Exigo amplifiers
EMT - Databases made with EMT 1.4 will now correctly set "use global settings" for SNMP on all devices
Control outputs can now be correctly reconfigured from fault indication to audio activity without rebooting the device
Volume control normalized for IP speakers and Exigo amplifiers
- Adjusting volume in zones with volume controls will now result in the same volume reduction for both IP speakers and Exigo amplifiers
Various typos fixed in fault message for ESC1 GUI
EMT - Volume settings are now availabile on all devices
EMT - Exigo 1.2 Databases can now be opened in EMT 1.4 and newer
EMT - Parallel wired devices will now be correctly configured
ESC1 - All latin letters including æøå supported in GUI
Exigo database is now completely deleted from AMC-IP board during a factory default
ESC1 - Internal network recovery mechanisms added
- In some installations glitches could occur which would disable the network interface until a reboot. Recovery mechanisms have been added to ensure the continuing operation of the network interface in such cases.
EMT - Volume Override Priority was not corectly fetched from the PSC with a GET operation
Programs will now merge correctly regardless of how Zone Selection is set up
Live speech will now always start correctly after a "rejected" call
- (1.3.3.1) If a call was rejected the operator would have to press twice on the live speech button to set up a new call. This is now fixed.