Difference between revisions of "Release Note Exigo 1.4"

From exigoWiki
Jump to navigation Jump to search
(Known issues)
(Access panel set in HD-mode with MB30G will not work correctly and audio might be corrupted)
 
(29 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
= Exigo 1.4.3.10 =
 +
 +
Release status: Official, available
 +
Release date: 10.11.2021
 +
Software collection file: EXIGO-1.4.3.10.zip
 +
 +
== Software included in EXIGO-1.4.3.10.zip ==
 +
 +
{| border="1"
 +
|+
 +
|'''Product'''
 +
|'''Version'''
 +
|'''Product description'''
 +
|-
 +
|VSF-Turbine
 +
|VSFT-4.10.3.8
 +
|Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
 +
|-
 +
|AlphaSys Firmware
 +
|13.0.3.12
 +
|Firmware for the ESC1 (Primary System Controller/AMC-IP board)  alpha-sys_13.0.3.12.apkg,  bsp_32.2.3.5.apkg
 +
|-
 +
|VS-EMT Exigo Management Tools
 +
|EMT-1.5.3.7
 +
|Configuration tool, installed on a Windows PC
 +
|-
 +
|VSF-Inca
 +
|02.20.3.12
 +
|Special Exigo software for the CRM-V based panel
 +
|-
 +
|VS-DEVICE-MIB
 +
|201806190000Z
 +
|SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools
 +
|-
 +
|}
 +
<br>
 +
 +
== Bugfixes and improvements ==
 +
 +
====MTN-3453 Exigo missing multicast reporting can now be delayed using the delay line error timer====
 +
Missing multicast is checked sequentially with a 0.1 sec delay between each device, and with a 5 sec delay for each round of pings. 6 subsequent missing pings trigger a fault for the device. The line_down_rep_delay can now be used to extend the timeout by allowing additional missing pings. The timer will scale based on connected devices and will therefore become larger for large systems.
 +
 +
====MTN-3368 Channel shutdown fix====
 +
Amplifier will turn off channel output when channel in shutdown, increased channel shutdown detection sensitivity
 +
 +
====MTN-3346 CO Fault indication fixed for A/B systems====
 +
CO Fault indication will correctly follow A or B system messages filter
 +
 +
====MTN-3207 EMT crashes on monitoring page====
 +
EMT crashing when trying to connect to the system under monitoring tab is now fixed.
 +
 +
====MTN-2787 ECPIR LED behaviour corrected for Live speech buttons====
 +
 +
====MTN-2242 EMT crashes on switching between operation and configuration tabs====
 +
EMT crashing when switching from operation to configuration tab is now fixed.
 +
 +
====MTN-2045 Corrected tool tip message for domain base address====
 +
Correct tool tip is displayed on System/Domain address settings based on multicast/unicast rule.
 +
 +
 +
= Exigo 1.4.3.9 =
 +
 +
Release status: Official, available
 +
Release date: 25.02.2021
 +
Software collection file: EXIGO-1.4.3.9.zip
 +
 +
== Software included in EXIGO-1.4.3.9.zip ==
 +
 +
{| border="1"
 +
|+
 +
|'''Product'''
 +
|'''Version'''
 +
|'''Product description'''
 +
|-
 +
|VSF-Turbine
 +
|VSFT-4.10.3.7
 +
|Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
 +
|-
 +
|AlphaSys Firmware
 +
|13.0.3.11
 +
|Firmware for the ESC1 (Primary System Controller/AMC-IP board)  alpha-sys_13.0.3.11.apkg,  bsp_32.2.3.5.apkg
 +
|-
 +
|VS-EMT Exigo Management Tools
 +
|EMT-1.5.3.6
 +
|Configuration tool, installed on a Windows PC
 +
|-
 +
|VSF-Inca
 +
|02.20.3.12
 +
|Special Exigo software for the CRM-V based panel
 +
|-
 +
|VS-DEVICE-MIB
 +
|201806190000Z
 +
|SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools
 +
|-
 +
|}
 +
<br>
 +
 +
== Bugfixes and improvements ==
 +
 +
==== Not able to scroll all the way down in System Menu ====
 +
There was a large change in System Menu UI between EMT version 1.4 and 1.5. Reverted back DockPanel inside ScrollViewer to get whole menu under the same scrollbar and added special handling for allowing mouse wheel input on entire menu.
 +
 +
==== Secondary System Controller registers as call panel ====
 +
Upgrading from 1.2 to 1.4 is not possible without rewriting the database in 1.4 version of EMT. Reason for that is because there were a lot of changes in ZAP config and device handling between those 2 versions, meaning some older config is not compatible with the new one anymore. One of the changes is reduction of used DIP registrations (numbers) that devices take on PSC in new SW version which could cause this issue.
 +
 +
==== EMT can select multicast addresses with number larger than 255 ====
 +
EMT will now calculate multicast addresses in a smarter way and still remain within the valid range.
 +
 +
==== Diagnostics feature gradually freezing up the ESC1/ENAxxxx ====
 +
A bug in the diagnostics feature allowed new and duplicated entries to be added to the status list. This kept on growing until the memory of the device was filled up, which in turn triggers a reboot of the system. This is now corrected.
 +
 +
==== Invalid source option in Live Speech on TKIS-2 kit ====
 +
EMT has changed, and this issue has been removed. Now it is possible to choose the TKIE as a source, and then configure the TKIE itself to use mic or line in.
 +
 +
= Exigo 1.4.3.8 =
 +
 +
Release status: Official, available
 +
Release date: 07.09.2020
 +
Software collection file: EXIGO-1.4.3.8.zip
 +
 +
== Software included in EXIGO-1.4.3.8.zip ==
 +
 +
{| border="1"
 +
|+
 +
|'''Product'''
 +
|'''Version'''
 +
|'''Product description'''
 +
|-
 +
|VSF-Turbine
 +
|VSFT-4.10.3.6
 +
|Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
 +
|-
 +
|AlphaSys Firmware
 +
|13.0.3.11
 +
|Firmware for the ESC1 (Primary System Controller/AMC-IP board)  alpha-sys_13.0.3.11.apkg,  bsp_32.2.3.5.apkg
 +
|-
 +
|VS-EMT Exigo Management Tools
 +
|EMT-1.4.3.8
 +
|Configuration tool, installed on a Windows PC
 +
|-
 +
|VSF-Inca
 +
|02.20.3.12
 +
|Special Exigo software for the CRM-V based panel
 +
|-
 +
|VS-DEVICE-MIB
 +
|201806190000Z
 +
|SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools
 +
|-
 +
|}
 +
<br>
 +
 +
== Bugfixes and improvements ==
 +
 +
==== New STIC (SIM) Card does not work for Exigo ====
 +
The new STIC card requires an updated driver in order for the system to read it correctly. The driver is updated and will now work with the new STIC.
 +
 +
= Exigo 1.4.3.7 =
 +
 +
Release status: LA
 +
Release date: 28.08.2020
 +
Software collection file: EXIGO-1.4.3.7.zip
 +
 +
== Software included in EXIGO-1.4.3.7.zip ==
 +
 +
{| border="1"
 +
|+
 +
|'''Product'''
 +
|'''Version'''
 +
|'''Product description'''
 +
|-
 +
|VSF-Turbine
 +
|VSFT-4.10.3.6
 +
|Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
 +
|-
 +
|AlphaSys Firmware
 +
|13.0.3.10
 +
|Firmware for the ESC1 (Primary System Controller/AMC-IP board)
 +
|-
 +
|VS-EMT Exigo Management Tools
 +
|EMT-1.4.3.8
 +
|Configuration tool, installed on a Windows PC
 +
|-
 +
|VSF-Inca
 +
|02.20.3.12
 +
|Special Exigo software for the CRM-V based panel
 +
|-
 +
|VS-DEVICE-MIB
 +
|201806190000Z
 +
|SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools
 +
|-
 +
|}
 +
<br>
 +
 +
== Bugfixes and improvements ==
 +
 +
==== ENA2xxx Channel 2 failed to report Line Status as Warning ====
 +
Regression where channel 2 reported line status as fault, even though configured to report it as warning, is corrected.
 +
 +
 +
= Exigo 1.4.3.6 =
 +
 +
Release status: LA
 +
Release date: 01.07.2020
 +
Software collection file: EXIGO-1.4.3.6.zip
 +
 +
== Software included in EXIGO-1.4.3.6.zip ==
 +
 +
{| border="1"
 +
|+
 +
|'''Product'''
 +
|'''Version'''
 +
|'''Product description'''
 +
|-
 +
|VSF-Turbine
 +
|VSFT-4.10.3.5
 +
|Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
 +
|-
 +
|AlphaSys Firmware
 +
|13.0.3.10
 +
|Firmware for the ESC1 (Primary System Controller/AMC-IP board)
 +
|-
 +
|VS-EMT Exigo Management Tools
 +
|EMT-1.4.3.8
 +
|Configuration tool, installed on a Windows PC
 +
|-
 +
|VSF-Inca
 +
|02.20.3.12
 +
|Special Exigo software for the CRM-V based panel
 +
|-
 +
|VS-DEVICE-MIB
 +
|201806190000Z
 +
|SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools
 +
|-
 +
|}
 +
<br>
 +
 +
== Bugfixes and improvements ==
 +
 +
==== Duplicate Device function ====
 +
The Duplicate Device function in EMT would not generate new StId's for the new device, so that multiple devices would have the same StId
 +
 +
==== Not possible to configure Backup Amplifier ====
 +
Adding a Backup Amplifier to the configuration in EMT would fail with an error message.
 +
 +
==== Live Speech Input Action on CIO fails ====
 +
It was not possible to configure Live Speech Input Action on Panel and Kit CIO's
 +
 +
==== Copy/Paste Output Action with custom description ====
 +
If CO with custom description is copy/pasted, it would result in some missing configuration.
 +
 +
==== Optimized call setup-time ====
 +
System controller software has been updated and optimized in order to keep the call set-up time low, even if a large number of BGM feeds are active.
 +
 +
= Exigo 1.4.3.5 =
 +
 +
Release status: Official, available
 +
Release date: 13.03.2020
 +
Software collection file: EXIGO-1.4.3.5.zip
 +
 +
== Software included in EXIGO-1.4.3.5.zip ==
 +
 +
{| border="1"
 +
|+
 +
|'''Product'''
 +
|'''Version'''
 +
|'''Product description'''
 +
|-
 +
|VSF-Turbine
 +
|VSFT-4.10.3.5
 +
|Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
 +
|-
 +
|AlphaSys Firmware
 +
|13.0.3.9
 +
|Firmware for the ESC1 (Primary System Controller/AMC-IP board)
 +
|-
 +
|VS-EMT Exigo Management Tools
 +
|EMT-1.4.3.7
 +
|Configuration tool, installed on a Windows PC
 +
|-
 +
|VSF-Inca
 +
|02.20.3.12
 +
|Special Exigo software for the CRM-V based panel
 +
|-
 +
|VS-DEVICE-MIB
 +
|201806190000Z
 +
|SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools
 +
|-
 +
|}
 +
<br>
 +
 +
== New Features ==
 +
==== Modbus interface ====
 +
The Exigo Controller implements a Modbus TCP slave (server) interface on the standard Modbus port, TCP port 502.
 +
The Modbus interface in Exigo has two main features:
 +
* Status about amplifiers and panels connected to the Controller can be read from a 16 bit Modbus Input Register.
 +
* PA calls and announcements can be triggered by writing to a Modbus Coil Register.
 +
Configuration of PA Calls and announcements is done through EMT.
 +
 +
==== Option to configure delay for Exigo Network Amplifiers ====
 +
It is now possible to add delay per channel per Exigo Network Amplifier.
 +
 +
== Bugfixes and improvements ==
 +
 +
==== Pilot tone turned off during suspend monitoring ====
 +
The pilot tone is turned off during suspend monitoring if no LETs in the system.
 +
 +
==== Amplifier Class D chip may crash when analog bypass is used ====
 +
When analog bypass is used on ENA2200/ENA2400, audio filters were not active which could cause Class D chip to crash. Analog bypass is now changed to Digital (SW) bypass that applies audio filters. <br>
 +
In Exigo Management Tool, the Amplifier output channel setting "HW Bypass Mode" on all ENA amplifier types is renamed to "Bypass Mode". <br>
 +
Also, the Bypass Mode can now be set individually for each Amplifier output channel on all ENA device types.
 +
 +
==== Improved System Controller performance ====
 +
Improved startup procedure in Exigo System Controller to allow loading of large configuration databases.
 +
 +
==== "Disable AVC" input-action creates toggle-action on key press_action event ====
 +
When adding the "Disable AVC" input-action to a key node, EMT previously created a start-action on the press_action event and stop-action on the release_action event. The behavior is changed so that a single toggle-action is created on the press_action event; nothing is triggered by the release_action event. In effect, this changes the AVC function to be disabled with one press on the configured key, and re-enabled with a consecutive press.
 +
 +
==== EMT: "Recall, Record" input action did not display "Wait for PTT flag" ====
 +
In EMT, when dropping a "Recall, Record" input action onto a Control Input, the "Wait for PTT" flag was not displayed. It was correctly displayed when dropped onto a CI on_action or off_action.
 +
 +
==== Program name change was not updated in configuration tree ====
 +
EMT needed to restart/reload database for an updated program name to be displayed correctly in the configuration tree.
 +
 +
== Known issues ==
 +
==== EAPIR-8 The Microphone input is not working ====
 +
 +
==== Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field ====
 +
 +
==== Tick tone will not be played out on access panels which is part of a zone ====
 +
 +
==== SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported ====
 +
 +
==== The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior ====
 +
 +
==== Flowire - For turning of monitoring of Flowire devices completely a full chilly restart must be done ====
 +
 +
==== EMT - Only one dialog box can be open if more than one EMT version is open ====
 +
 
= Exigo 1.4.3.4 =
 
= Exigo 1.4.3.4 =
  
Line 502: Line 840:
 
==== Access panel set in HD-mode with MB30G will not work correctly and audio might be corrupted ====
 
==== Access panel set in HD-mode with MB30G will not work correctly and audio might be corrupted ====
 
: All access panels are now default set to Voice mode to prevent errors.
 
: All access panels are now default set to Voice mode to prevent errors.
 +
 +
[[Category:Release notes]]

Latest revision as of 07:59, 10 May 2022

Contents

Exigo 1.4.3.10

Release status: Official, available
Release date: 10.11.2021
Software collection file: EXIGO-1.4.3.10.zip

Software included in EXIGO-1.4.3.10.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.8 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.12 Firmware for the ESC1 (Primary System Controller/AMC-IP board) alpha-sys_13.0.3.12.apkg, bsp_32.2.3.5.apkg
VS-EMT Exigo Management Tools EMT-1.5.3.7 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

MTN-3453 Exigo missing multicast reporting can now be delayed using the delay line error timer

Missing multicast is checked sequentially with a 0.1 sec delay between each device, and with a 5 sec delay for each round of pings. 6 subsequent missing pings trigger a fault for the device. The line_down_rep_delay can now be used to extend the timeout by allowing additional missing pings. The timer will scale based on connected devices and will therefore become larger for large systems.

MTN-3368 Channel shutdown fix

Amplifier will turn off channel output when channel in shutdown, increased channel shutdown detection sensitivity

MTN-3346 CO Fault indication fixed for A/B systems

CO Fault indication will correctly follow A or B system messages filter

MTN-3207 EMT crashes on monitoring page

EMT crashing when trying to connect to the system under monitoring tab is now fixed.

MTN-2787 ECPIR LED behaviour corrected for Live speech buttons

MTN-2242 EMT crashes on switching between operation and configuration tabs

EMT crashing when switching from operation to configuration tab is now fixed.

MTN-2045 Corrected tool tip message for domain base address

Correct tool tip is displayed on System/Domain address settings based on multicast/unicast rule.


Exigo 1.4.3.9

Release status: Official, available
Release date: 25.02.2021
Software collection file: EXIGO-1.4.3.9.zip

Software included in EXIGO-1.4.3.9.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.7 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.11 Firmware for the ESC1 (Primary System Controller/AMC-IP board) alpha-sys_13.0.3.11.apkg, bsp_32.2.3.5.apkg
VS-EMT Exigo Management Tools EMT-1.5.3.6 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

Not able to scroll all the way down in System Menu

There was a large change in System Menu UI between EMT version 1.4 and 1.5. Reverted back DockPanel inside ScrollViewer to get whole menu under the same scrollbar and added special handling for allowing mouse wheel input on entire menu.

Secondary System Controller registers as call panel

Upgrading from 1.2 to 1.4 is not possible without rewriting the database in 1.4 version of EMT. Reason for that is because there were a lot of changes in ZAP config and device handling between those 2 versions, meaning some older config is not compatible with the new one anymore. One of the changes is reduction of used DIP registrations (numbers) that devices take on PSC in new SW version which could cause this issue.

EMT can select multicast addresses with number larger than 255

EMT will now calculate multicast addresses in a smarter way and still remain within the valid range.

Diagnostics feature gradually freezing up the ESC1/ENAxxxx

A bug in the diagnostics feature allowed new and duplicated entries to be added to the status list. This kept on growing until the memory of the device was filled up, which in turn triggers a reboot of the system. This is now corrected.

Invalid source option in Live Speech on TKIS-2 kit

EMT has changed, and this issue has been removed. Now it is possible to choose the TKIE as a source, and then configure the TKIE itself to use mic or line in.

Exigo 1.4.3.8

Release status: Official, available
Release date: 07.09.2020
Software collection file: EXIGO-1.4.3.8.zip

Software included in EXIGO-1.4.3.8.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.6 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.11 Firmware for the ESC1 (Primary System Controller/AMC-IP board) alpha-sys_13.0.3.11.apkg, bsp_32.2.3.5.apkg
VS-EMT Exigo Management Tools EMT-1.4.3.8 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

New STIC (SIM) Card does not work for Exigo

The new STIC card requires an updated driver in order for the system to read it correctly. The driver is updated and will now work with the new STIC.

Exigo 1.4.3.7

Release status: LA
Release date: 28.08.2020
Software collection file: EXIGO-1.4.3.7.zip

Software included in EXIGO-1.4.3.7.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.6 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.10 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.8 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

ENA2xxx Channel 2 failed to report Line Status as Warning

Regression where channel 2 reported line status as fault, even though configured to report it as warning, is corrected.


Exigo 1.4.3.6

Release status: LA
Release date: 01.07.2020
Software collection file: EXIGO-1.4.3.6.zip

Software included in EXIGO-1.4.3.6.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.5 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.10 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.8 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

Duplicate Device function

The Duplicate Device function in EMT would not generate new StId's for the new device, so that multiple devices would have the same StId

Not possible to configure Backup Amplifier

Adding a Backup Amplifier to the configuration in EMT would fail with an error message.

Live Speech Input Action on CIO fails

It was not possible to configure Live Speech Input Action on Panel and Kit CIO's

Copy/Paste Output Action with custom description

If CO with custom description is copy/pasted, it would result in some missing configuration.

Optimized call setup-time

System controller software has been updated and optimized in order to keep the call set-up time low, even if a large number of BGM feeds are active.

Exigo 1.4.3.5

Release status: Official, available
Release date: 13.03.2020
Software collection file: EXIGO-1.4.3.5.zip

Software included in EXIGO-1.4.3.5.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.5 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.9 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.7 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


New Features

Modbus interface

The Exigo Controller implements a Modbus TCP slave (server) interface on the standard Modbus port, TCP port 502. The Modbus interface in Exigo has two main features:

  • Status about amplifiers and panels connected to the Controller can be read from a 16 bit Modbus Input Register.
  • PA calls and announcements can be triggered by writing to a Modbus Coil Register.

Configuration of PA Calls and announcements is done through EMT.

Option to configure delay for Exigo Network Amplifiers

It is now possible to add delay per channel per Exigo Network Amplifier.

Bugfixes and improvements

Pilot tone turned off during suspend monitoring

The pilot tone is turned off during suspend monitoring if no LETs in the system.

Amplifier Class D chip may crash when analog bypass is used

When analog bypass is used on ENA2200/ENA2400, audio filters were not active which could cause Class D chip to crash. Analog bypass is now changed to Digital (SW) bypass that applies audio filters.
In Exigo Management Tool, the Amplifier output channel setting "HW Bypass Mode" on all ENA amplifier types is renamed to "Bypass Mode".
Also, the Bypass Mode can now be set individually for each Amplifier output channel on all ENA device types.

Improved System Controller performance

Improved startup procedure in Exigo System Controller to allow loading of large configuration databases.

"Disable AVC" input-action creates toggle-action on key press_action event

When adding the "Disable AVC" input-action to a key node, EMT previously created a start-action on the press_action event and stop-action on the release_action event. The behavior is changed so that a single toggle-action is created on the press_action event; nothing is triggered by the release_action event. In effect, this changes the AVC function to be disabled with one press on the configured key, and re-enabled with a consecutive press.

EMT: "Recall, Record" input action did not display "Wait for PTT flag"

In EMT, when dropping a "Recall, Record" input action onto a Control Input, the "Wait for PTT" flag was not displayed. It was correctly displayed when dropped onto a CI on_action or off_action.

Program name change was not updated in configuration tree

EMT needed to restart/reload database for an updated program name to be displayed correctly in the configuration tree.

Known issues

EAPIR-8 The Microphone input is not working

Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field

Tick tone will not be played out on access panels which is part of a zone

SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported

The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior

Flowire - For turning of monitoring of Flowire devices completely a full chilly restart must be done

EMT - Only one dialog box can be open if more than one EMT version is open

Exigo 1.4.3.4

Release status: Official, available
Release date: 04.11.2019
Software collection file: EXIGO-1.4.3.4.zip

Software included in EXIGO-1.4.3.4.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.4 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.7 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.4 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

Backup Amplifier Remote Control

There is a new function to control Take Over and Release functions of Backup Amplifiers. The function is available in EMT Operation Pane.

Option to pulse the SSC fault relay on new faults

Added an option for the SSC fault relay to pulse (turn off and on again) on new faults, or when faults reappear.

External relay for industrial stations not working

This is now corrected and the correct gpio is now used for external relays

Known issues

EAPIR-8 The Microphone input is not working

Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field

Tick tone will not be played out on access panels which is part of a zone

SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported

The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior

Flowire - For turning of monitoring of Flowire devices completely a full chilly restart must be done

EMT - Only one dialog box can be open if more than one EMT version is open

Exigo 1.4.3.3

Release status: Official, available
Release date: 03.09.2019
Software collection file: EXIGO-1.4.3.3.zip

Software included in EXIGO-1.4.3.3.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.2 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.6 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.2 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

Exigo Controller DSP Fault Result in Missing Audio

In the unlikely situation of the A-Controller DSP processor stops working, audio from messages and alarm generator will be missing.
This situation is now avoided by lowering priority of the A-controller when DSP fault detected. This will assure usage of B-controller audio in the system.

Known issues

Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field

Tick tone will not be played out on access panels which is part of a zone

SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported

The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior

Flowire - For turning of monitoring of Flowire devices completely a full chilly restart must be done

EMT - Only one dialog box can be open if more than one EMT version is open

Exigo 1.4.3.2

Release status: LA
Release date: 27.06.2019
Software collection file: EXIGO-1.4.3.2.zip

Software included in EXIGO-1.4.3.2.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.2 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.4 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.2 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

Configurable Cancel Tone on Live Speech

New EMT system setting for turning off the audible cancel tone played out in the Panel after live speech. Default setting is ON.

Use IP Speaker as AVC Source

It is now possible to use AVC Source Device as AVC Receiver. This makes it possible to connect a microphone to an IP Speaker and use this as AVC Source Device.

ENA2100-AC was missing a critical high pass filter

This could lead to destroying the class-d modules with audio in low frequencies

Known issues

Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field

Tick tone will not be played out on access panels which is part of a zone

SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported

The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior

Flowire - For turning of monitoring of Flowire devices completely a full chilly restart must be done

EMT - Only one dialog box can be open if more than one EMT version is open

Exigo 1.4.3.1

Release status: LA
Release date: 27.05.2019
Software collection file: EXIGO-1.4.3.1.zip

Software included in EXIGO-1.4.3.1.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.1 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.3 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.0 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


Bugfixes and improvements

SIP Trunk Stations Should Only Use Trunk License

SIP trunk stations now allocate SIP trunk license when in call. Previously each configured SIP trunk station required a SIP station license.
  • For customers using SIP trunk stations, previously used SIP station licenses will not be used after upgrade.
  • The maximum number of simultaneous SIP trunk stations in call, will relate to the number of SIP trunk licenses in the system.
Please consult Customer Service if SIP station licenses needed to be converted to SIP trunk licenses.

Lamp test would adversly affect time-limited blinking leds

LED's which were blinking (example due to a live speech timeout) would lock and continue to blink after the lamp test was finished.

Unicast was missing call information related to volume settings

Volume settings would not work on Exigo amplifiers set to receive unicast from PSC

SNMPv2c getBulkrequest issues fixed

SNMP now correctly handles bulk requests with multiple OID which goes beyond one OID. This would previously crash the SNMP process and restart the device.

Issue related to multiple call escalations

Fixed an issue where multiple call escalation IDs on a call with always include zones and clear call escalation on first activity would not work correctly in combination.

Fixed issue with HD-Mode where audio would leak between two channels on one amplifier

Exigo systems under high load could in some cases send PA messages in some additional zones for a few seconds.

VAD configured on a line input will no longer trigger "read ip adress" if a control input is shorted

Fixed an issue where configured VAD would cause the amplifier to read its IP-address if the amplifier was started before the PSC was ready.

VAD will now continue to work after a reboot

VAD stopped working after a reboot due to a mismatch in configuration

ReCall from SIP trunk

Activating the ReCall function from a SIP trunk using codec G711, did not play out the recorded message. Fixed.

ZAP can now be used to set volume levels on all amplifiers and kits

Volume override can now be used correctly with advanced volume control

Volume override can now be used both on channels and zones to force max volume if an activity has a priority above a configured level

Fixed memory leak on control inputs with external fault

Device with a external fault on a control input would reboot after around 9000 activations due to a memory leak in libstpanels json handling.

Option "Replace" on call type Live Speech

It is now possible to use the option Replace on call type Live Speech.

Known issues

Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field

Tick tone will not be played out on access panels which is part of a zone

SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported

The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior

Flowire - For turning of monitoring of flowire devices completly a full chilly restart must be done

EMT - Only one dialog box can be open if more than one EMT version is open

Exigo 1.4.3.0

Release status: Official, available
Release date: 10.12.2018
Software collection file: EXIGO-1.4.3.0.zip

Software included in EXIGO-1.4.3.0.zip

Product Version Product description
VSF-Turbine VSFT-4.10.3.0 Firmware for the following devices: ESC1(Secondary System Controller), ENA2100, ENA2200, ENA2400, ECPIR-3P, ECPIR-P, EAPIR-8, EAPFX-1, EAPFX-6, EAPII-1, EAPII-6, TKIS-2, TKIE-2, IP-LCM.
AlphaSys Firmware 13.0.3.0 Firmware for the ESC1 (Primary System Controller/AMC-IP board)
VS-EMT Exigo Management Tools EMT-1.4.3.0 Configuration tool, installed on a Windows PC
VSF-Inca 02.20.3.12 Special Exigo software for the CRM-V based panel
VS-DEVICE-MIB 201806190000Z SNMP MIB for Exigo EXI-Devices, for upload in 3rd-party SNMP based monitoring tools


New Features

IP-LCM support in Alphacom / Pulse / SIP

IP-LCM is now supported in Exigo systems. This device have:
  • 8 robust high power relays
  • 8 robust inputs
  • Powered via the TKIS-2 kit with PoE, PoE inject or external power supply
  • All connections and features from the TKIS-2 kit available

Exigo systems can now be integrated with Pulse systems

Using the SIP interface on Exigo systems allows for integration both ways to pulse systems

EMT - Scan IP range for devices now available

New tool in Operation view to scan an IP range for Exigo devices. From the list of discovered devices it is possible to send a command to the device to make the fault led blink (works for ENA, Access Panel and SSC devices).
By default, the fault led will blink 4 times, 2 blinks pr second. The number of blinks and blink rate can be changed in Options -> Configuration Options.
From the list of discovered devices it is also possible to open the device's Web Configuration page in the default browser.

SNMP traps are now supported by all Exigo devices

SNMP traps for faults are now supported by all Exigo devices. Configuration is done via EMT.

Exigo now supports distributed automatic volume controllers

Distributed Automatic Volume Controllers (dAVC) is TKIS-2 kits which measures background noise in an area and can adjust the volume settings for an amplifier or IP speaker so that the audio is audible above the noise.
  • DAVC devices is monitored as other devices in the Exigo system.
  • Zones with dAVC devices can have "volume override" functionality. Activities with priorities above this threshold will use full volume efficiently ignore background noise adjustments.
  • DAVC Control of zone can be based on: highest, average or average mid. Both average require at least four dAVC devices.
  • Disable AVC function can be used to selectively disable dAVC functionality per zone.
  • Adjustment mode can be positive or negative between two thresholds.
  • Advanced options where attack rate, decay rate, hysteresis and lock out time are available

ENA2100-AC is now supported in Exigo systems

  • Advanced line monitoring and Lets supported
  • Hardware audio bypass supported
  • 2 control outputs with 200mA@24Vdc each
  • 2 control inputs
  • Supported in Exigo mode and Alphacom systems

New ZAP rpcs available for remote integration

  • Restart of Class-D module
  • Identification of devices by toggling fault led
  • Remote toggling of control outputs

Audio bypass is now supported on all Exigo devices

Bypass will route audio directly from the line input to both audio output channels based on the following configuration choices:
  • Always on: This allows the amplifier to operate standalone mode without ESC1 or Alphacom
  • Idle: This allows the amplifier to have bypass activated when no digital audio is present.
  • No connection: This allows the amplifier to activate bypass if it loose connection to ESC1 or Alphacom
  • Always off: This is default for Exigo amplifiers and audio bypass will never be activated
ENA2100-AC: Hardware bypass available for instant forwarding
ENA2200, ENA2400-DC, ENA2400-AC: Audio bypass available after software is up

Zone select can now deselect when activities are started or stopped

This gives more options to how zone select should behave in relation to activities started from the access panels

Adjustable delay of missing devices

It is now possible on a per device level to adjust a delay before the device is reported missing. Default is 0 seconds of delay before the device is reported missing.

Bugfixes and improvements

Detailed channel state in SNMP MIB

Detailed information about the actual state of the audio channel is now included in the SNMP MIB.

Access panels part of zones can now correctly receive messages, alarms and live speech

EMT - Database will handle Exigo Net system ID settings better

EMT - An error window without effect would sometimes appear when changing the name of a zone

EMT - Actions can now be copied to paired devices successfully

Headphone output on ENA2200 and ENA2400 will now not be active unless activated from the GUI

Improved handling of audio streams on amplifiers

EMT - "Always include" field removed from local mute action

AMC-IP will now correctly remove Exigo settings immediatly after a factory default

EMT - Password for PSC can now be changed

EMT - Advanced program control sequence can now be correctly copy/pasted

TKIE-2 relay 2 can now be configured correctly without rebooting the device

Program volume control function can now use dynamically selected zones

EMT - PSC will now reboot correctly if changes to the SIP interface is done

A manual reboot was necessary for any changes to be enabled and this will happen automatically now.

EMT - Tooltip for zone selection is now correct

EMT - EMT can now correclty generate a database directly from a GET when controller B is missing

EMT - Zone names with illegal characters will now not be allowed

Incoming SIP Calls will now be correctly parsed

Sometimes the source nummer of an incoming SIP call would add a digit

EMT - Name of zone will now always save when the done button is pressed

EMT - Improvements to zone handling when an access panel is added to the zone

Voice activity detection can now be used on EX panels to automatically trigger actions

EMT - Getting a database from a running system will now correctly get any volume adjustments done to the Exigo amplifiers

EMT - Databases made with EMT 1.4 will now correctly set "use global settings" for SNMP on all devices

Control outputs can now be correctly reconfigured from fault indication to audio activity without rebooting the device

Volume control normalized for IP speakers and Exigo amplifiers

Adjusting volume in zones with volume controls will now result in the same volume reduction for both IP speakers and Exigo amplifiers

Various typos fixed in fault message for ESC1 GUI

EMT - Volume settings are now availabile on all devices

EMT - Exigo 1.2 Databases can now be opened in EMT 1.4 and newer

EMT - Parallel wired devices will now be correctly configured

ESC1 - All latin letters including æøå supported in GUI

Exigo database is now completely deleted from AMC-IP board during a factory default

ESC1 - Internal network recovery mechanisms added

In some installations glitches could occur which would disable the network interface until a reboot. Recovery mechanisms have been added to ensure the continuing operation of the network interface in such cases.

EMT - Volume Override Priority was not corectly fetched from the PSC with a GET operation

Programs will now merge correctly regardless of how Zone Selection is set up

Live speech will now always start correctly after a "rejected" call

(1.3.3.1) If a call was rejected the operator would have to press twice on the live speech button to set up a new call. This is now fixed.

Recall is now correctly timing out if timeout is used

EMT - Clear all activity will now not have destination field if "all" is selected

EMT - Adding an amplifier to more than one zone will now always generate a "multiple zones" warning

Live speech with "wait for PTT" and no dynamic zones selected will now not light the green led

Non-existing power sources reported as faulty

ECPIR volume settings can now be adjusted even if the access panel is not connected to a server

Call escalation with no zones selected will now correctly be ignored instead of crashing the access panel

Exigo devices will now listen to the same NTP server if more than one is configured

(Bug 1.3.3.1) Dummy zones which does not contain devices can now be correctly called again

EMT - Keys on main panel will sort first for devices which use EMBDR-8

EMT - Zones could loose name if "done" was not pressed

The list of possible faults on the Exigo wiki is now updated

Fault Indication System Message

EMT - Volume settings for access panels available

EMT will automatically reset AMC-IP when new SIP devices have been added

Exigo Amplifier web pages and SNMP text normalized

It is now possible to configure which call states that follow alarm should operate in

Volume adjustment function now blink green one time to indicate a change and red if limit is met

EMT now shows version in window name

Increased system capacity

Exigo now supports up to 16 simultanious audio activities.

SIP advance integration: Call id

Exigo will now strip all non-numeric characters from SIP calls

The Configure Stations menu on the AMC-IP web is now disabled in Exigo Mode

Known issues

Fault indication - It is possible to change from "or" to "and" between fields, but not inside one field

Tick tone will not be played out on access panels which is part of a zone

SIP devices for integration can only have directory numbers with numbers. Alphanumeric numbers are not supported

The same fault ID can not be used on different buttons on an access panel - This will result in wrong LED behavior

Flowire - For turning of monitoring of Flowire devices completely a full chilly restart must be done

EMT - Only one dialog box can be open if more than one EMT version is open

Access panel set in HD-mode with MB30G will not work correctly and audio might be corrupted

All access panels are now default set to Voice mode to prevent errors.