Difference between revisions of "Flowire Monitoring"

From exigoWiki
Jump to navigation Jump to search
(EMT Configuration)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
[[File:Flowire.png|thumb|right|350px|Flowire]]
 
[[File:Flowire.png|thumb|right|350px|Flowire]]
This article describes how to enable monitoring for the Flowires that are connected to the Exigo system.<br>
+
This article describes how to enable monitoring for the [https://wiki.zenitel.com/wiki/Flowire Flowires] that are connected to the Exigo system.<br>
  
 
Monitoring the Flowires will provide better error reporting and easier troubleshooting if an error should occur.
 
Monitoring the Flowires will provide better error reporting and easier troubleshooting if an error should occur.
  
 
== EMT Configuration ==
 
== EMT Configuration ==
Monitoring of the Flowires must be configured using [[EMT]].<br>
+
Monitoring of the Flowires must be configured using [[:Category:EMT|EMT]].<br>
 
* Go to '''Configuration''' view  
 
* Go to '''Configuration''' view  
 
* In the device tree, go to '''System''' > '''Flowires'''
 
* In the device tree, go to '''System''' > '''Flowires'''

Latest revision as of 13:25, 3 January 2020

Flowire

This article describes how to enable monitoring for the Flowires that are connected to the Exigo system.

Monitoring the Flowires will provide better error reporting and easier troubleshooting if an error should occur.

EMT Configuration

Monitoring of the Flowires must be configured using EMT.

  • Go to Configuration view
  • In the device tree, go to System > Flowires
EMT - Flowires


  • Click the Add button (beside the trashcan) to add a new Flowire to the system.
  • Click the Trashcan button to remove monitoring of the selected Flowire.
EMT - Flowires


Feature: This is automatically generated by EMT. The first Flowire will have flow001, the next flow002 and so on.

Display Name: It is recommended to give the Flowire a descriptive name. The name will be displayed in the fault list if a Flowire loses a connection.
A good descriptive name will make it easier to troubleshoot if a fault occurs.

Flowire Configuration

Configuration of the Flowire is done via the web interface of the Flowire.
If there is no DHCP server on the network, the Flowire unit will, by default, have a static IP address 169.254.1.10.

  • Log into the web interface of the Flowire
Flowire Web Interface


  • Click the Upgrade form button
Flowire Web Interface


  • Click the EXIGO form button
Flowire Web Interface


Enter values for the following configuration parameters:
DOMAIN_ADDRESS: This is the IP address of the Primary System Controller (PSC).

DOMAIN_PORT: This is the ZAP port number being used by Exigo. The default port number is 50004.

USERNAME: The username is the Feature that is automatically generated by EMT. The first Flowire will have flow001, the next flow002 and so on.

Availability

This function is available from Exigo 1.3 and later.