Difference between revisions of "Setting up a small system"
(→Step 1: IP address and Directory number) |
(→Step 1: IP address and Directory number) |
||
Line 9: | Line 9: | ||
== Step 1: IP address and Directory number == | == Step 1: IP address and Directory number == | ||
Each device will need to be configured with an '''IP address''' and subnet which is in range of the AMC-IP card.<br> | Each device will need to be configured with an '''IP address''' and subnet which is in range of the AMC-IP card.<br> | ||
− | In addition each device also need a [[Directory Numbers | '''directory number''']] | + | In addition each device also need a [[Directory Numbers | '''directory number''']]. |
Table below lists IP range for a small system with one amplifier and on access panel.<br> | Table below lists IP range for a small system with one amplifier and on access panel.<br> |
Revision as of 13:43, 26 January 2017
This article explains how to setup and configure a small Exigo system with one ESC1 Controller, one ENA2200 Amplifier and one ECPIR-3P Access panel. The system will be programmed with 2 Zones. With the PPT button we will configure Live Speech on both zones.
Before you start configure make sure that all devices have been updated to the latest software/firmware.
Contents
- 1 Step 1: IP address and Directory number
- 2 Step 2: Primary System Controller Setup
- 3 Step 3: Secondary System Controller Setup
- 4 Step 4: ENA Amplifier Setup
- 5 Step 5: ECPIR-3P Setup
- 6 Step 6: Install Exigo Management Tool (EMT)
- 7 Step 7: Exigo Management Tool Setup
- 8 Step 8: Exigo Management Tool System Configuration
- 9 Step 9: Upload database
Step 1: IP address and Directory number
Each device will need to be configured with an IP address and subnet which is in range of the AMC-IP card.
In addition each device also need a directory number.
Table below lists IP range for a small system with one amplifier and on access panel.
All subnets are set to 255.255.255.0
Default Gateway is set to 10.1.0.1
Device | IP | Directory number |
---|---|---|
PSC | 10.1.0.21 | |
ESC1 | 10.1.0.20 | 013010 |
ENA | 10.1.0.30 | 012010 |
ECPIR-3P | 10.1.0.50 | 011010 |
Step 2: Primary System Controller Setup
Open up the front of the ESC1 System Controller. Connect your computer to eth0.
- Open a web browser and enter the default IP address of port npe_eth0: 169.254.1.5
- Log in with username: admin and password: alphaadmin
- Select System Configuration > Interfaces
- Enter the appropriate IP address (10.1.10.21) in the npe_eth1 field.
Step 3: Secondary System Controller Setup
Connect your computer to eth1 (on the back of the ESC1 System Controller).
To find the IP address of the Secondary System Controller:
- Turn the menu selection knob on the system controller to select Settings > Network to see the IP address on the display.
To configure the IP address and directory number:
- Open a web browser and enter IP address: 169.254.x.x
- Log in with username: admin and password: alphaadmin
- Select Station Main > Main Settings
Set the following values:
- Station Mode: Use Exigo
- Registration Settings:
- Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
- Directory Number: 013010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
- IP Settings: Static IP
- IP-address: 10.1.0.20
- Subnet-mask: 255.255.255.0
- Gateway: 10.1.0.1
Step 4: ENA Amplifier Setup
Connect your computer to eth1 (on the back of the ENA Amplifier).
To find the IP address of the ENA Amplifier:
- Turn the menu selection knob on the Amplifier to select Settings > Network to see the IP address on the display.
To configure the IP address and directory number:
- Open a web browser and enter IP address: 169.254.x.x
- Log in with username: admin and password: alphaadmin
- Select Station Main > Main Settings
Set the following values:
- Station Mode: Use Exigo
- Registration Settings:
- Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
- Directory Number: 012010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
- IP Settings: Static IP
- IP-address: 10.1.0.30
- Subnet-mask: 255.255.255.0
- Gateway: 10.1.0.1
Step 5: ECPIR-3P Setup
Configuration is done via the access panel’s web interface. After making sure that the access panel is connected to the same LAN and logical subnet as your PC, follow the procedure described below.
To configure the IP address and directory number:
- Open a web browser and enter IP address: 169.254.x.x
- Log in with username: admin and password: alphaadmin
- Select Station Main > Main Settings
Set the following values:
- Station Mode: Use Exigo
- Registration Settings:
- Primary System Controller address: 10.1.0.21 (IP address previously set for PSC)
- Directory Number: 011010 (corresponds to the Directory Number automatically assigned to the system controller in the Exigo Management Tool)
- IP Settings: Static IP
- IP-address: 10.1.0.50
- Subnet-mask: 255.255.255.0
- Gateway: 10.1.0.1
Step 6: Install Exigo Management Tool (EMT)
Install EMT on your computer. See this page for details: Installing EMT
Step 7: Exigo Management Tool Setup
- Start the Exigo Management Tool
- Click Projects at the lower-left of the window.
- Click New
- Click the New Database tab
- Click the right-arrow icon at the bottom of the window
- Enter a project name in the Project field
- Select the A-B System tab
- Click the right-arrow icon at the bottom of the window
- Set 2 for the Number of Discrete Zones
- Enter IP address 10.1.0.21 in Domain Address
- Click the right-arrow icon at the bottom of the window
Select the desired monitoring:
- Select Eth1 for the Rack Devices
- Select AC Monitoring
- Select Eth1 for the Access Panels and Kits
Select the desired Advanced Settings:
- Default setting is OK. This can be changed later if needed.
- Click the right-arrow icon at the bottom of the window to display a project summary
- Click Finish to complete the setup of the project
After setup, your Exigo system should look something like the following:
Step 8: Exigo Management Tool System Configuration
When the Project is created in EMT it is time to do configuration on the System.
Assigning the ECPIR-3P Access Panel to the System:
- Click Components at the lower-left of the window.
- Click Devices from the menu box
- Under Console Mounted Access Panels drag-and-drop ECPIR-3P to System
The access panel will now appear as ECPIR-3P 1 in the device list under System.
Assigning Channels on Amplifier to Zones:
- Select ENA2200 A1 > Audio Lines > Line > Amplifier output channel 1
- Drag-and-drop Amplifier output channel 1 to Zone 1 under PA Zones
- Repeat the procedure to assign channel 2 on the amplifiers to Zone 2.
Assigning Zone to the PPT Button
- Select System > ECPIR-3P 1 > Programmable Keys > ptt > press_actions
- In the detailed view select All under Destination
Do the same for release_action:
- Select System > ECPIR-3P 1 > Programmable Keys > ptt > press_release
- In the detailed view select All under Destination
Step 9: Upload database
In the Navigation pane, select Projects view.
- Press Send to upload the new configuration to the Exigo system
The system shall now be working. If you push PTT it shall be possible to make a live speech to both zones.