Difference between revisions of "Follow Any Alarm Tone"

From exigoWiki
Jump to navigation Jump to search
(Parameter details)
Line 12: Line 12:
 
#Drag '''Follow Any Alarm Tone''' to the '''Control Output''' you want to use.
 
#Drag '''Follow Any Alarm Tone''' to the '''Control Output''' you want to use.
  
[[File:Follow any alarm tone 2.JPG|thumb|left|500px|Assigning Fault Indication funtion to a Control Output]]
+
[[File:Follow any alarm tone 2.JPG|thumb|left|500px|Assigning Fault Indication function to a Control Output]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  

Revision as of 11:20, 12 August 2016

The control output follows the alarm tone in Zone 1

Control Outputs are configured by defining one or more actions to be triggered on an output event.

The Follow Any Alarm Tone function is used to trigger the control output to follow any alarm tone in one specific zone.


Assigning Follow Any Alarm Tone to a Control Output

To assign the function Follow Any Alarm Tone to an Control Output:

  1. In Components view, open Output Actions
  2. In System, identify the Controller, the Amplifier or the Access Panel to be used, and expand to Device > Control Outputs.
  3. Drag Follow Any Alarm Tone to the Control Output you want to use.
Assigning Fault Indication function to a Control Output


Configuration

Follow alarm tone in Zone 1

  1. Drag Follow Any Alarm Tone to the desired Control Output.
  2. Select the desired Alarm (or Any) in Source.
  3. Select Zone 1 in Zone.
Assigning Fault Indication funtion to a Control Output


In this example the General Alarm (Ship) in Zone 1 will trig Control Output 1.

Parameter details

Idle State: Sets the idle state for the output. The options are Normally Open or Normally Closed

Delay Activation: Delays control output activation for the stipulated number of seconds when triggered.

Source: The source that will trigger the alarm output. If Source is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not.

Zone: The zones in which the output on an activity is triggered. If Zone is not specified, it will be ignored when checking whether the conditions for the audio activity triggering are present or not. Note that only one zone can be specified.

Priority Range: The priority range within which the activity is triggered.

Advanced Options:

Limit High Not OK: When the Control Output is cleared, and feedback voltage is at or above this value, the output is considered fed with alien voltage.
Limit Low OK: When the Control Output is set, and feedback voltage is above this value, the output is considered active OK.