Difference between revisions of "Line Measurement"

From exigoWiki
Jump to navigation Jump to search
(Created page with "Line Measurement is used for the manual control of line monitoring of the system. Manual line monitoring can be set on each channel of the amplifier. When line monitoring is s...")
 
Line 1: Line 1:
 
Line Measurement is used for the manual control of line monitoring of the system. Manual line monitoring can be set on each channel of the amplifier. When line monitoring is set to manual, this function will, based on zone selection, enable line measurement for at least 5 minutes. During this period, the line will be measured against previous calibrations. To calibrate for the first time, the Activation parameter must be set to Start. This will initiate the process for the channels to be calibrated. Typically, there will be an input on a rack device that should be enabled. Under such a measurement, all COs configured with Line Measurement will be toggled in the selected zones. For example, these can be used to turn off volume controllers.
 
Line Measurement is used for the manual control of line monitoring of the system. Manual line monitoring can be set on each channel of the amplifier. When line monitoring is set to manual, this function will, based on zone selection, enable line measurement for at least 5 minutes. During this period, the line will be measured against previous calibrations. To calibrate for the first time, the Activation parameter must be set to Start. This will initiate the process for the channels to be calibrated. Typically, there will be an input on a rack device that should be enabled. Under such a measurement, all COs configured with Line Measurement will be toggled in the selected zones. For example, these can be used to turn off volume controllers.
 +
 +
 +
 +
[[Category:Exigo features]]

Revision as of 16:23, 10 February 2016

Line Measurement is used for the manual control of line monitoring of the system. Manual line monitoring can be set on each channel of the amplifier. When line monitoring is set to manual, this function will, based on zone selection, enable line measurement for at least 5 minutes. During this period, the line will be measured against previous calibrations. To calibrate for the first time, the Activation parameter must be set to Start. This will initiate the process for the channels to be calibrated. Typically, there will be an input on a rack device that should be enabled. Under such a measurement, all COs configured with Line Measurement will be toggled in the selected zones. For example, these can be used to turn off volume controllers.