Difference between revisions of "Flowire Compatibility Overview"
Jump to navigation
Jump to search
(Created page with "This article explains the compatibility between the different Flowire units and the different software versions. There are 3 different Flowire models: *FCDC1 *FCDC2 *...") |
|||
(8 intermediate revisions by the same user not shown) | |||
Line 5: | Line 5: | ||
*[[FCDC2]] | *[[FCDC2]] | ||
*[[FCDC3]] | *[[FCDC3]] | ||
+ | |||
+ | The following table shows software versions needed in FCDC1/2 or EX-stations to achieve compatibility between FCDC3 and FCDC1, FCDC2 and EX-stations. <br> | ||
+ | Old software for FCDC1/2 and EX-stations is 4.1.3.12 and older. <br> | ||
+ | New software for FCDC1/2 and EX-stations is 4.1.3.13 and newer. <br> | ||
+ | |||
+ | |||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! scope="col"| Stations | ||
+ | ! scope="col"| FCDC3 | ||
+ | ! scope="col"| FCDC1/2 & <br>EX-Station w/old SW | ||
+ | ! scope="col"| FCDC1/2 & <br>EX-Station w/new SW | ||
+ | |- | ||
+ | ! scope="row"| FCDC3 | ||
+ | | Full compatibility | ||
+ | | No connection | ||
+ | | Full compatibility | ||
+ | |- | ||
+ | ! scope="row"| FCDC1/2 & <br>EX-Station w/old SW | ||
+ | | No connection | ||
+ | | Full compatibility | ||
+ | | Limited compatibility <br>(upgrade possible) | ||
+ | |- | ||
+ | ! scope="row" | FCDC1/2 & <br>EX-Station w/new SW | ||
+ | | Full compatibility | ||
+ | | Limited compatibility <br>(upgrade possible) | ||
+ | | Full compatibility | ||
+ | |} | ||
+ | |||
+ | {{Note}} ''Updating EX-stations to version 4.1.2.13 '''must''' be done by using a FCDC1/2.'' | ||
+ | |||
+ | == Spare Part Scenarios == | ||
+ | === Redundant Exigo A-B configuration === | ||
+ | # Replacing a FCDC1/2 or EX-stations with old software with FCDC1/2 or same type EX-station with old software: No additional actions needed. | ||
+ | # Replacing one or more of the FCDC1/2 with old software with FCDC3 in a system with FCDC1/2 or EX-stations still in cluster: Update remaining FCDC1/2 and EX-stations with new software. Update of EX-stations '''must''' be done using a FCDC1/2. | ||
+ | |||
+ | [[Category:Hardware]] | ||
+ | [[Category:Software upgrade]] |
Latest revision as of 14:11, 3 February 2020
This article explains the compatibility between the different Flowire units and the different software versions.
There are 3 different Flowire models:
The following table shows software versions needed in FCDC1/2 or EX-stations to achieve compatibility between FCDC3 and FCDC1, FCDC2 and EX-stations.
Old software for FCDC1/2 and EX-stations is 4.1.3.12 and older.
New software for FCDC1/2 and EX-stations is 4.1.3.13 and newer.
Stations | FCDC3 | FCDC1/2 & EX-Station w/old SW |
FCDC1/2 & EX-Station w/new SW |
---|---|---|---|
FCDC3 | Full compatibility | No connection | Full compatibility |
FCDC1/2 & EX-Station w/old SW |
No connection | Full compatibility | Limited compatibility (upgrade possible) |
FCDC1/2 & EX-Station w/new SW |
Full compatibility | Limited compatibility (upgrade possible) |
Full compatibility |
Updating EX-stations to version 4.1.2.13 must be done by using a FCDC1/2.
Spare Part Scenarios
Redundant Exigo A-B configuration
- Replacing a FCDC1/2 or EX-stations with old software with FCDC1/2 or same type EX-station with old software: No additional actions needed.
- Replacing one or more of the FCDC1/2 with old software with FCDC3 in a system with FCDC1/2 or EX-stations still in cluster: Update remaining FCDC1/2 and EX-stations with new software. Update of EX-stations must be done using a FCDC1/2.