Revision as of 08:27, 13 June 2019
This article describes the SNMP parameters that are recommended to monitor.
Exigo 1.2.3.13
Exigo 1.2.3.13 is using SNMPv1.
OID | Logical name | Frequency | Unit | Priority |
---|---|---|---|---|
Memory usage MIB2 | Memory usage | Once every 60 second | All | |
1.3.6.1.4.1.26122.3.1.4 | infoAmplifierType | During startup | All | |
1.3.6.1.4.1.26122.3.1.1 | infoPackageVersion | During startup | All | |
1.3.6.1.4.1.26122.3.2 | temp | |||
1.3.6.1.4.1.26122.3.2.1 | tempTableCount | |||
1.3.6.1.4.1.26122.3.2.2.1.2 | tempSensorName | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.2.2.1.7 | tempAverageString | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.2.2.1.8 | tempAverageValue | Twice every 60 second | SSC + ENA | |
1.3.6.1.4.1.26122.3.3 | fan | |||
1.3.6.1.4.1.26122.3.3.1 | fanTableCount | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.3.2.1.2 | fanString | During startup | SSC + ENA | |
1.3.6.1.4.1.26122.3.3.2.1.3 | fanValue | Once every 60 second | SSC + ENA | |
1.3.6.1.4.1.26122.3.7 | ampChannel | |||
1.3.6.1.4.1.26122.3.7.1 | ampChannelCount | During startup | ENA | |
1.3.6.1.4.1.26122.3.7.3.1.2 | ampChannelString | During startup | ENA | |
1.3.6.1.4.1.26122.3.7.3.1.3 | ampChannelStatus: unknown(1), notOperative(2), channelOk(3), channelFail(4), channelShutdown(5), channelGracefulDegradation(6) | Once every 60 second | ENA | High |
1.3.6.1.4.1.26122.3.6 | lineIn | Panels |