Difference between revisions of "EPIPR-6"

From exigoWiki
Jump to navigation Jump to search
(Overview - Back)
 
(7 intermediate revisions by the same user not shown)
Line 5: Line 5:
 
== Installation ==
 
== Installation ==
 
===Overview - Front===
 
===Overview - Front===
[[File:EPIPR-6 Overview.PNG|left]]
+
[[File:EPIPR-6 Overview.PNG|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
{| border="1"
 
{| border="1"
Line 23: Line 23:
  
 
===Overview - Back===
 
===Overview - Back===
[[File:EPIPR-6 back Connections.PNG|left]]
+
[[File:Epipr 6 back connection.PNG|left|400px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
{| border="1"
 
{| border="1"
 
|  align="center" style="background:#ffd400;" width="50pt"| 1 || align="left"  | Input ports || align="left"| Ethernet port for connection to the central switch
 
|  align="center" style="background:#ffd400;" width="50pt"| 1 || align="left"  | Input ports || align="left"| Ethernet port for connection to the central switch
 +
|-
 +
|  align="center" style="background:#ffd400;" width="50pt"| 2 || align="left"  | Mounting clip || align="left"| Plastic clip to mount the EPIPR-6 unit to a DIN rail
 
|-
 
|-
 
|  align="center" style="background:#ffd400;" width="50pt"| 2 || align="left"  | Power input || align="left"| Power connection for power to the PoE devices
 
|  align="center" style="background:#ffd400;" width="50pt"| 2 || align="left"  | Power input || align="left"| Power connection for power to the PoE devices
Line 51: Line 53:
 
to RJ45 terminal blocks or patch panels in the equipment rack.  
 
to RJ45 terminal blocks or patch panels in the equipment rack.  
  
   [[File:Warning.PNG]]
+
   {{Warn}}
 
  '''''Do not connect the outputs of the EPIPR-6 to equipment other than spare pair PoE'''''
 
  '''''Do not connect the outputs of the EPIPR-6 to equipment other than spare pair PoE'''''
 
  '''''enabled field equipment as this may damage the equipment if the Ethernet is not '''''
 
  '''''enabled field equipment as this may damage the equipment if the Ethernet is not '''''
Line 58: Line 60:
 
  '''''EPIPR-6.'''''
 
  '''''EPIPR-6.'''''
  
==Dimensions==
+
== Dimensions ==
 
[[File:EPIPR-6 Dimensions.PNG]]
 
[[File:EPIPR-6 Dimensions.PNG]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />

Latest revision as of 12:26, 4 May 2018

EPIPR-6.
EPIPR-6

Exigo Power Injector, Spare Pair PoE, 6 Ports

Installation

Overview - Front

EPIPR-6 Overview.PNG


1 Output ports Ethernet ports carrying data and power
2 Power switch Power switch to individually turn on/off spare pair PoE on the output ports
3 Fuses Replaceable fuse for each output port
4 DIN mounting clip Plastic clip to mount the EPIPR-6 unit to a DIN rail
5 Lid retention clip Small plastic clip which must be depressed to remove the top cover



Overview - Back

Epipr 6 back connection.PNG


1 Input ports Ethernet port for connection to the central switch
2 Mounting clip Plastic clip to mount the EPIPR-6 unit to a DIN rail
2 Power input Power connection for power to the PoE devices



Placement

When used in an equipment rack, the EPIPR-6 can be mounted at any accessible location.

Mounting

The EPIPR-6 is a DIN-rail mounted device, and hence requires a DIN rail. The DIN rail shall be mounted securely to the equipment rack, and properly stabilized. The DIN clips on the EPIPR-6 shall be properly secured to the DIN rail.

Power Supply

The EPIPR-6 unit itself requires no power to operate. The voltage supplied to the unit is only inserted on the spare pairs of the Cat cable. The voltage required by the PoE standard is 48 VDC, and hence the Exigo access panels require the same 48 VDC.

The 48 VDC to the EPIPR-6 unit can either be supplied by the same power as the network switch, or by separate power supplies. The power supply feeding the EPIPR-6 must be duplicated, i.e. connected to the equipment rack’s primary and secondary power supplies in the case of a single system. In the case of an A-B system, the access panels will be supplied by one EPIPR-6 unit in each equipment rack, maintaining the requirement for power redundancy.

Ethernet Connections

The Ethernet connections from the input ports shall be routed to the central switch in the equipment rack using UTP Cat5 cables or better. The output Ethernet connections shall be routed to RJ45 terminal blocks or patch panels in the equipment rack.

 Warning.png
Do not connect the outputs of the EPIPR-6 to equipment other than spare pair PoE
enabled field equipment as this may damage the equipment if the Ethernet is not 
properly terminated internally. If the output must be connected to such equipment,
make sure to disable the spare pair PoE by turning the switch internally in the
EPIPR-6.

Dimensions

EPIPR-6 Dimensions.PNG

Additional Documentation

For more documentation, please visit the Zenitel web page: https://www.zenitel.com/product/epipr-6