Difference between revisions of "Volume Control"
(→Parameter details) |
|||
Line 1: | Line 1: | ||
− | This article describe the Volume Control feature.<br> | + | This article describe the Volume Control feature.<br><br> |
− | With the use of an DAK or control input it is possible to increase and decrease volume in selected zone(s). | + | With the use of an DAK or control input it is possible to increase and decrease volume in selected zone(s) or directly on the channels. The last volume adjustment done will be the active one. |
== Assigning Volume Control to a Control Input == | == Assigning Volume Control to a Control Input == |
Revision as of 10:32, 21 September 2017
This article describe the Volume Control feature.
With the use of an DAK or control input it is possible to increase and decrease volume in selected zone(s) or directly on the channels. The last volume adjustment done will be the active one.
Assigning Volume Control to a Control Input
Assigning Volume Control to a DAK:
- Drag Volume Control to the «press_action» on the desired key
Parameter details
Step Direction: Up - Volume increase, Down Volume decrease.
Step Size: Step size in dB (decibel). Maximum 10 dB, minimum 1 dB.
Minimum Volume: Minimum volume that can be selected.
Destination: The Zone(s) and/or output(s) that is affected. This may be left blank if access panel keys are used for dynamic zone selection.
Override pre-selected Zones by Zone Select: Selecting this will override the pre-selected zone if dynamic zone selection is used.
Availability
This function is available on Exigo 1.3.3 and newer.