:1. While '''pressing any button''', power up the station by connecting to a PoE switch. | :1. While '''pressing any button''', power up the station by connecting to a PoE switch. | ||
Line 21: | Line 21: | ||
== Reset to Factory Default Settings with Static IP == | == Reset to Factory Default Settings with Static IP == | ||
− | [[File:EAPII factory default2.PNG|thumb| | + | [[File:EAPII factory default2.PNG|thumb|250px|Factory Default with Static IP Address]] |
To reset: | To reset: | ||
:1. While '''pressing any button''', power up the station by connecting to a PoE switch. | :1. While '''pressing any button''', power up the station by connecting to a PoE switch. |
Revision as of 11:28, 8 February 2018
A EAPII access panel may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
Preparation
- Connect a loudspeaker (8 ohms or higher) to the speaker output
Reset to Factory Default Settings with Activated DHCP
To reset:
- 1. While pressing any button, power up the station by connecting to a PoE switch.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 5 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button to make the station say its IP address.
Factory default values
- Station IP address: (determined by DHCP server)
- Username: admin
- Password: alphaadmin
Reset to Factory Default Settings with Static IP
To reset:
- 1. While pressing any button, power up the station by connecting to a PoE switch.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 3 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button to make the station say its IP address.
Factory default values
- Station IP address: 169.254.1.100
- Username: admin