This article explains the different default configuration settings available in Exigo.
The Default Configuration has 3 sections:
- Rack Devices
- Access Panels and Kits
- System Settings
The settings are located under System -> Default Configuration.
Rack Devices
- Eth Port Monitoring - enable/disable monitoring of the Ethernet ports.
- AC Monitoring - enable/disable monitoring of the AC power.
- DC Monitoring - enable/disable monitoring of the DC power.
- Amplifier Line Voltage - 100 Volt or 70 Volt.
- Report Line Faults as Warning - Line Faults will be reported as Warnings instead of Faults.
- Missing Device Reporting - In Primary, In Both or None.
Access Panels and Kits
- Eth Port Monitoring - enable/disable monitoring of the Ethernet ports.
- Missing Device Reporting - In Primary, In Both or None.
System Settings
- Override Volume Control on Priority - select the priority where the Override Volume Control will be enabled.
- Audio Device Mode - select Voice or HD Audio. More information here.
- No Beep on Call End - if set this turns off the cancel tone.
- Missing Unregistered Device Report Time - Defines the time (in seconds) after startup when the Controller starts reporting 'Missing Device'.
- Enable - Unchecking will turn off Missing Unregistered Device Reporting.
- Delay 'Missing Device' Report - if set, suppress 'Missing Device' report for devices if the device is missing for less time than the limit set in 'Missing Debounce Time'.
- Missing Debounce Time - Delay for debouncing 'Missing Device' reports.